MODEL3116-T71-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI OBJECT-GROUP FROM SNMPv2-CONF; model3116-T71 MODULE-IDENTITY LAST-UPDATED "200906080900Z" ORGANIZATION "Cross Technologies" CONTACT-INFO "info@crosstechnologies.com 770-886-8005" DESCRIPTION "Mib Module for Cross Technologies model 3116-T71 frequency translator" REVISION "200906080900Z" DESCRIPTION "Version 1.0 This is the initial version." ::= { enterprises crosstechRoot(31210) model3116-T71(20) } -- Mib module for Cross Technologies Model 3116-T71 UHF to UHF converters model3116T71objects OBJECT IDENTIFIER ::= { model3116-T71 1 } model3116T71groups OBJECT IDENTIFIER ::= { model3116-T71 2 } --Variables to report and modify for Model 3116-T71 band-3116-T71 OBJECT-TYPE SYNTAX INTEGER(1 .. 7) UNITS "none" MAX-ACCESS read-write STATUS current DESCRIPTION "Band Number -- 1: 5.85-6.95 Ghz In, 3.4-4.5 Ghz Out; 2: 7.9-8.4 Ghz In, 7.25-7.75 Ghz Out; 3: 13.75-14.85 Ghz In, 10.7-11.8 Ghz Out; 4: 13.75-14.85 Ghz In, 11.7-12.8 Ghz Out; 5: 13.75-14.85 Ghz In, 11.7-12.8 Ghz Out; 6: 17.3-18.4 Ghz In, 10.7-11.8 Ghz Out; 7: 17.3-18.4 Ghz In, 11.7-12.8 Ghz Out." ::= { model3116T71objects 1 } gain-3116-T71 OBJECT-TYPE SYNTAX INTEGER(-40 .. 20) UNITS "dB" MAX-ACCESS read-write STATUS current DESCRIPTION "Gain -- settable in 1 dB steps." ::= { model3116T71objects 2 } loFreqOsB1-3116-T71 OBJECT-TYPE SYNTAX INTEGER(-400 .. 600) UNITS "Mhz" MAX-ACCESS read-write STATUS current DESCRIPTION "LO Frequency Offset for Band #1." ::= { model3116T71objects 3 } loFreqOsB2-3116-T71 OBJECT-TYPE SYNTAX INTEGER(0) UNITS "Mhz" MAX-ACCESS read-write STATUS current DESCRIPTION "LO Frequency Offset for Band #2. (This band is not adjustable.)" ::= { model3116T71objects 4 } loFreqOsB3-3116-T71 OBJECT-TYPE SYNTAX INTEGER(-1000 .. 0) UNITS "Mhz" MAX-ACCESS read-write STATUS current DESCRIPTION "LO Frequency Offset for Band #3." ::= { model3116T71objects 5 } loFreqOsB4-3116-T71 OBJECT-TYPE SYNTAX INTEGER(0 .. 1000) UNITS "Mhz" MAX-ACCESS read-write STATUS current DESCRIPTION "LO Frequency Offset for Band #4." ::= { model3116T71objects 6 } loFreqOsB5-3116-T71 OBJECT-TYPE SYNTAX INTEGER(-260 to 300) UNITS "Mhz" MAX-ACCESS read-only STATUS current DESCRIPTION "LO Frequency Offset for Band #5." ::= { model3116T71objects 7 } loFreqOsB6-3116-T71 OBJECT-TYPE SYNTAX INTEGER(0) UNITS "Mhz" MAX-ACCESS read-write STATUS current DESCRIPTION "LO Frequency Offset for Band #6. (This band is not adjustable.)" ::= { model3116T71objects 8 } loFreqOsB7-3116-T71 OBJECT-TYPE SYNTAX INTEGER(-500 to 0) UNITS "Mhz" MAX-ACCESS read-write STATUS current DESCRIPTION "LO Frequency Offset for Band #7." ::= { model3116T71objects 9 } loFreqB1-3116-T71 OBJECT-TYPE SYNTAX INTEGER(2050 .. 3050) UNITS "Mhz" MAX-ACCESS read-only STATUS current DESCRIPTION "LO Frequency for Band #1. I.e., nominal frequency + offset." ::= { model3116T71objects 10 } loFreqB2-3116-T71 OBJECT-TYPE SYNTAX INTEGER(650) UNITS "Mhz" MAX-ACCESS read-only STATUS current DESCRIPTION "LO Frequency for Band #2. I.e., nominal frequency + offset." ::= { model3116T71objects 11 } loFreqB3-3116-T71 OBJECT-TYPE SYNTAX INTEGER(2050 .. 3050) UNITS "Mhz" MAX-ACCESS read-only STATUS current DESCRIPTION "LO Frequency for Band #3. I.e., nominal frequency + offset." ::= { model3116T71objects 12 } loFreqB4-3116-T71 OBJECT-TYPE SYNTAX INTEGER(2050 .. 3050) UNITS "Mhz" MAX-ACCESS read-only STATUS current DESCRIPTION "LO Frequency for Band #4. I.e., nominal frequency + offset." ::= { model3116T71objects 13 } loFreqB5-3116-T71 OBJECT-TYPE SYNTAX INTEGER(1240 .. 1800) UNITS "Mhz" MAX-ACCESS read-only STATUS current DESCRIPTION "LO Frequency for Band #5. I.e., nominal frequency + offset." ::= { model3116T71objects 14 } loFreqB6-3116-T71 OBJECT-TYPE SYNTAX INTEGER(6600) UNITS "Mhz" MAX-ACCESS read-only STATUS current DESCRIPTION "LO Frequency for Band #6. I.e., nominal frequency + offset." ::= { model3116T71objects 15 } loFreqB7-3116-T71 OBJECT-TYPE SYNTAX INTEGER(5100 .. 5600) UNITS "Mhz" MAX-ACCESS read-only STATUS current DESCRIPTION "LO Frequency for Band #7. I.e., nominal frequency + offset." ::= { model3116T71objects 16 } refMode-3116-T71 OBJECT-TYPE SYNTAX INTEGER(1 .. 3) UNITS "none" MAX-ACCESS read-write STATUS current DESCRIPTION "This number indicates/sets the mode of the reference source. There are 3 modes as follows. [1] internal; [2] external; [3] auto. In auto, the external reference source is used but if unavailable, the unit automatically switches to internal. " ::= { model3116T71objects 17 } refOffset-3116-T71 OBJECT-TYPE SYNTAX INTEGER(-2000 .. 2000) UNITS "none" MAX-ACCESS read-write STATUS current DESCRIPTION "This number is an adjustment to the 10 Mhz reference frequency. This is available to fine tune the reference source. " ::= { model3116T71objects 18 } mute-3116-T71 OBJECT-TYPE SYNTAX INTEGER(0 .. 1) UNITS "none" MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates/sets the muting of the unit. The unit may be manually muted by setting this value to 1. The unit might automatically mute itself when an alarm condition occurs in which case this value will show 1. The value will be 0 if the unit is not muted. " ::= { model3116T71objects 19 } refStatus-3116-T71 OBJECT-TYPE SYNTAX INTEGER(0 .. 1) MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the actual source of the 10MHz reference in use. 0 is internal, 1 is external. " ::= { model3116T71objects 20 } temperature-3116-T71 OBJECT-TYPE SYNTAX INTEGER(-99 .. 99) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the internal PCB temperature measured in degrees C. " ::= { model3116T71objects 21 } ovenWarmup-3116-T71 OBJECT-TYPE SYNTAX INTEGER(0 .. 1) MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the status of the internal reference oven. 0 = oven warmup is OFF; 1 = oven warmup is ON. " ::= { model3116T71objects 22 } alarmStatus-3116-T71 OBJECT-TYPE SYNTAX INTEGER(0 .. 1) MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates if the unit's alarm is ON(1) or OFF(0). " ::= { model3116T71objects 23 } --Object groups model3116T71objectGroup OBJECT-GROUP OBJECTS {band-3116-T71, gain-3116-T71, loFreqOsB1-3116-T71, loFreqOsB2-3116-T71, loFreqOsB3-3116-T71, loFreqOsB4-3116-T71, loFreqOsB5-3116-T71, loFreqOsB6-3116-T71, loFreqOsB7-3116-T71, loFreqB1-3116-T71, loFreqB2-3116-T71, loFreqB3-3116-T71, loFreqB4-3116-T71, loFreqB5-3116-T71, loFreqB6-3116-T71, loFreqB7-3116-T71, refMode-3116-T71, refOffset-3116-T71, mute-3116-T71, refStatus-3116-T71, temperature3116-T71, ovenWarmup3116-T71, alarmStatus3116-T71} STATUS current DESCRIPTION "All objects to control and monitor Model 3116-T71" ::= { model3116T71groups 1 } END